+
  • undefined

JC-1000 of filter respirator detection device

Products include: fire breathing apparatus, fire fighting equipment, fire testing equipment, hardware tools, energy saving and environmental protection products, handicrafts and other products professional production and processing

Fire filter type self-rescue respirator detector is a comprehensive technical content of high testing equipment, before the domestic few manufacturers can develop and produce, so many respirator manufacturers mostly do not have this kind of testing equipment, can only be commissioned by the national fire testing center inspection. Our company combined with Zhejiang University, through many years of technical research, finally developed a JC-1000 type fire filter type self-rescue respirator testing device, the device adopts imported infrared transmitter and advanced digital processing technology, to achieve the respirator CO gas protection performance of continuous automatic rapid online detection. Functions: 1) Detect the tightness of the respirator mask. 2) Detect the CO concentration before and after filtering, and the temperature and humidity of the gas before and after filtering. 3) Detect the CO gas protection time and protection performance of the respirator. 4) Measure the inspiratory resistance, expiratory resistance and inspiratory temperature of the respirator. Features of the instrument: imported infrared sensor is adopted, with long service life, high sensitivity and fast response speed. it comes with precision filter, which greatly improves the service life of the sensor. the upper and lower limit control points can be set arbitrarily within the full range of data backup and data recovery function standard 4-20mA standard RS232/RS485 communication full Chinese operation menu technical parameters: measurement range: detection gas detection minimum range detection maximum range carbon monoxide CO 0-1000ppm 0-1% accuracy: ≤ 2% F.S stability: zero drift: 1.5 F.S/30d range drift: 1.5 F.S/30d sample gas flow rate: 500 mL/min sample gas pressure: 0.1Mpa ≤ inlet pressure ≤ 0.25Mpa output signal: 4 ~ 20mA or 0 ~ 5VDC optional contact capacity: 24VDC,1A working environment: temperature:-5 ℃ ~ +45 ℃ humidity: ≤ 90% RH

Key words:

JC-1000 of filter respirator detection device

Classification:

Product Consulting:

Product Description

Common fire fighting equipment includes fire extinguisher, fire hydrant, fire axe, fire alarm bell, fire filter breathing apparatus, fire hose, fire detector, etc. Fire fighting equipment refers to the equipment used for fire fighting, fire prevention and fire accidents. The fire extinguishing methods are isolation fire extinguishing method, cooling fire extinguishing method and suffocation fire extinguishing method. Fire extinguishing apparatus includes heptafluoropropane fire extinguishing device, carbon dioxide fire extinguisher, 1211 fire extinguisher, dry powder fire extinguisher, acid reducing foam fire extinguisher, carbon tetrachloride fire extinguisher, fire extinguisher hanger, mechanical foam fire extinguisher, water type fire extinguisher, other fire extinguishing apparatus, etc.

Picture Name

Fire filter type self-rescue respirator detector is a comprehensive technical content of high testing equipment, before the domestic few manufacturers can develop and produce, so many respirator manufacturers mostly do not have this kind of testing equipment, can only be commissioned by the national fire testing center inspection. Our company combined with Zhejiang University, through many years of technical research, finally developed a JC-1000 type fire filter type self-rescue respirator testing device, the device adopts imported infrared transmitter and advanced digital processing technology, to achieve the respirator CO gas protection performance of continuous automatic rapid online detection. Functions: 1) Detect the tightness of the respirator mask. 2) Detect the CO concentration before and after filtering, and the temperature and humidity of the gas before and after filtering. 3) Detect the CO gas protection time and protection performance of the respirator. 4) Measure the inspiratory resistance, expiratory resistance and inspiratory temperature of the respirator. Features of the instrument: imported infrared sensor is adopted, with long service life, high sensitivity and fast response speed. it comes with precision filter, which greatly improves the service life of the sensor. the upper and lower limit control points can be set arbitrarily within the full range of data backup and data recovery function standard 4-20mA standard RS232/RS485 communication full Chinese operation menu technical parameters: measurement range: detection gas detection minimum range detection maximum range carbon monoxide CO 0-1000ppm 0-1% accuracy: ≤ 2% F.S stability: zero drift: 1.5 F.S/30d range drift: 1.5 F.S/30d sample gas flow rate: 500 mL/min sample gas pressure: 0.1Mpa ≤ inlet pressure ≤ 0.25Mpa output signal: 4 ~ 20mA or 0 ~ 5VDC optional contact capacity: 24VDC,1A working environment: temperature:-5 ℃ ~ +45 ℃ humidity: ≤ 90% RH

Related Products


Get free product quotes